{"id":1769,"date":"2026-04-03T14:12:16","date_gmt":"2026-04-03T11:12:16","guid":{"rendered":"https:\/\/metrolab.cen.aboutdev.gr\/?p=1769"},"modified":"2026-04-03T14:12:16","modified_gmt":"2026-04-03T11:12:16","slug":"adp600-series-multi-wavelength-and-temperature-controlled-polarimeters","status":"publish","type":"post","link":"https:\/\/metrolab.gr\/en\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\/","title":{"rendered":"ADP600 Series Multi-Wavelength and Temperature Controlled Polarimeters"},"content":{"rendered":"<p><strong>Bellingham + Stanley\u2019s ADP600 Series digital polarimeters<\/strong>\u00a0are high accuracy instruments that measure optical rotation and are available as single, dual and multiple wavelength derivatives that cover the visible spectrum as well as up to four decimal places in the highly sensitive ultra-violet region. This capability of measuring across the broad spectrum makes the instrument ideal for use by scientists wishing to measure chiral compounds and other optically active substances in the chemical, pharmaceutical and food sectors as well as for those in academic research.<\/p>\n<p><strong>XPC Temperature Control<\/strong><\/p>\n<p>Xylem\u2019s patented XPC technology directly controls the temperature of the sample chamber, allowing for fast temperature stabilisation that is more representative of the sample than the air surrounding it.<\/p>\n<p><strong>Connectivity &amp; Security<\/strong><\/p>\n<p>RFID user clearance comes as standard in the\u00a0<strong>ADP600 Series Polarimeters<\/strong>, which was first introduced in the\u00a0<strong>ADP400 Series Polarimeters<\/strong>. Additionally the\u00a0<strong>ADP600 Series Polarimeters<\/strong>\u00a0feature a\u00a0<strong>secure \u201cprint to PDF\u201d function\u00a0<\/strong>that may be configured to operate in secure environments in accordance with\u00a0<strong>FDA regulation 21 CFR Part 11\u00a0<\/strong>and importantly, the\u00a0<strong>ADP600 Series polarimeters<\/strong>\u00a0meet all of the requirements, including wavelength directives of\u00a0<strong>British, United States, European and Japanese Pharmacopoeia<\/strong>.<\/p>\n<p>&nbsp;<\/p>\n<p>Find more information about the available ADP600 Series Multi-Wavelength Polarimeters models\u00a0<a href=\"https:\/\/www.bellinghamandstanley.com\/en\/polarimeters\/adp-600-series-polarimeters\" target=\"_blank\" rel=\"noopener\">here<\/a>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Bellingham + Stanley\u2019s ADP600 Series digital polarimeters\u00a0are high accuracy instruments that measure optical rotation and are available as single, dual and multiple wavelength derivatives that cover the visible spectrum as well as up to four decimal places in the highly sensitive ultra-violet region. This capability of measuring across the broad spectrum makes the instrument ideal for use by scientists wishing to measure chiral compounds and other optically active substances in the chemical, pharmaceutical and food sectors as well as for those in academic research.<\/p>","protected":false},"author":2,"featured_media":1764,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[75],"tags":[],"class_list":["post-1769","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-polosimetra"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>ADP600 Series Multi-Wavelength and Temperature Controlled Polarimeters - MetroLab<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/metrolab.gr\/en\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ADP600 Series Multi-Wavelength and Temperature Controlled Polarimeters - MetroLab\" \/>\n<meta property=\"og:description\" content=\"Bellingham + Stanley\u2019s ADP600 Series digital polarimeters\u00a0are high accuracy instruments that measure optical rotation and are available as single, dual and multiple wavelength derivatives that cover the visible spectrum as well as up to four decimal places in the highly sensitive ultra-violet region. This capability of measuring across the broad spectrum makes the instrument ideal for use by scientists wishing to measure chiral compounds and other optically active substances in the chemical, pharmaceutical and food sectors as well as for those in academic research.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/metrolab.gr\/en\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\/\" \/>\n<meta property=\"og:site_name\" content=\"MetroLab\" \/>\n<meta property=\"article:published_time\" content=\"2026-04-03T11:12:16+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/metrolab.gr\/wp-content\/uploads\/2026\/04\/Bellingham-Stanley_ADP600_2021.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t<meta property=\"og:image:height\" content=\"300\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"praktiki\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"praktiki\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/metrolab.gr\\\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/metrolab.gr\\\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\\\/\"},\"author\":{\"name\":\"praktiki\",\"@id\":\"https:\\\/\\\/metrolab.gr\\\/#\\\/schema\\\/person\\\/b98de2eb332dfc3d427dc3608e835c04\"},\"headline\":\"ADP600 Series Multi-Wavelength and Temperature Controlled Polarimeters\",\"datePublished\":\"2026-04-03T11:12:16+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/metrolab.gr\\\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\\\/\"},\"wordCount\":211,\"publisher\":{\"@id\":\"https:\\\/\\\/metrolab.gr\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/metrolab.gr\\\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/metrolab.gr\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/Bellingham-Stanley_ADP600_2021.jpg\",\"articleSection\":[\"\u03a0\u03bf\u03bb\u03c9\u03c3\u03af\u03bc\u03b5\u03c4\u03c1\u03b1\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/metrolab.gr\\\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\\\/\",\"url\":\"https:\\\/\\\/metrolab.gr\\\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\\\/\",\"name\":\"ADP600 Series Multi-Wavelength and Temperature Controlled Polarimeters - MetroLab\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/metrolab.gr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/metrolab.gr\\\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/metrolab.gr\\\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/metrolab.gr\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/Bellingham-Stanley_ADP600_2021.jpg\",\"datePublished\":\"2026-04-03T11:12:16+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/metrolab.gr\\\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/metrolab.gr\\\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/metrolab.gr\\\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\\\/#primaryimage\",\"url\":\"https:\\\/\\\/metrolab.gr\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/Bellingham-Stanley_ADP600_2021.jpg\",\"contentUrl\":\"https:\\\/\\\/metrolab.gr\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/Bellingham-Stanley_ADP600_2021.jpg\",\"width\":300,\"height\":300},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/metrolab.gr\\\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/metrolab.gr\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ADP600 Series Multi-Wavelength and Temperature Controlled Polarimeters\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/metrolab.gr\\\/#website\",\"url\":\"https:\\\/\\\/metrolab.gr\\\/\",\"name\":\"MetroLab\",\"description\":\"\u0388\u03bd\u03b1\u03c2 \u03c3\u03c5\u03bd\u03b5\u03c1\u03b3\u03ac\u03c4\u03b7\u03c2, \u03c7\u03b9\u03bb\u03b9\u03ac\u03b4\u03b5\u03c2 \u03b5\u03c0\u03b9\u03bb\u03bf\u03b3\u03ad\u03c2 \u03b3\u03b9\u03b1 \u03c4\u03bf \u03b5\u03c1\u03b3\u03b1\u03c3\u03c4\u03ae\u03c1\u03b9\u03cc \u03c3\u03b1\u03c2\",\"publisher\":{\"@id\":\"https:\\\/\\\/metrolab.gr\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/metrolab.gr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/metrolab.gr\\\/#organization\",\"name\":\"MetroLab\",\"url\":\"https:\\\/\\\/metrolab.gr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/metrolab.gr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/metrolab.gr\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/logo_metrolab-1@2x-1.png\",\"contentUrl\":\"https:\\\/\\\/metrolab.gr\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/logo_metrolab-1@2x-1.png\",\"width\":409,\"height\":108,\"caption\":\"MetroLab\"},\"image\":{\"@id\":\"https:\\\/\\\/metrolab.gr\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/metrolab.gr\\\/#\\\/schema\\\/person\\\/b98de2eb332dfc3d427dc3608e835c04\",\"name\":\"praktiki\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a717692306270715324e48aa870b6be5b99691d4444d8bb03ece104d00acd956?s=96&d=monsterid&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a717692306270715324e48aa870b6be5b99691d4444d8bb03ece104d00acd956?s=96&d=monsterid&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a717692306270715324e48aa870b6be5b99691d4444d8bb03ece104d00acd956?s=96&d=monsterid&r=g\",\"caption\":\"praktiki\"},\"url\":\"https:\\\/\\\/metrolab.gr\\\/en\\\/author\\\/praktiki\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ADP600 Series Multi-Wavelength and Temperature Controlled Polarimeters - MetroLab","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/metrolab.gr\/en\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\/","og_locale":"en_GB","og_type":"article","og_title":"ADP600 Series Multi-Wavelength and Temperature Controlled Polarimeters - MetroLab","og_description":"Bellingham + Stanley\u2019s ADP600 Series digital polarimeters\u00a0are high accuracy instruments that measure optical rotation and are available as single, dual and multiple wavelength derivatives that cover the visible spectrum as well as up to four decimal places in the highly sensitive ultra-violet region. This capability of measuring across the broad spectrum makes the instrument ideal for use by scientists wishing to measure chiral compounds and other optically active substances in the chemical, pharmaceutical and food sectors as well as for those in academic research.","og_url":"https:\/\/metrolab.gr\/en\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\/","og_site_name":"MetroLab","article_published_time":"2026-04-03T11:12:16+00:00","og_image":[{"width":300,"height":300,"url":"https:\/\/metrolab.gr\/wp-content\/uploads\/2026\/04\/Bellingham-Stanley_ADP600_2021.jpg","type":"image\/jpeg"}],"author":"praktiki","twitter_card":"summary_large_image","twitter_misc":{"Written by":"praktiki","Estimated reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/metrolab.gr\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\/#article","isPartOf":{"@id":"https:\/\/metrolab.gr\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\/"},"author":{"name":"praktiki","@id":"https:\/\/metrolab.gr\/#\/schema\/person\/b98de2eb332dfc3d427dc3608e835c04"},"headline":"ADP600 Series Multi-Wavelength and Temperature Controlled Polarimeters","datePublished":"2026-04-03T11:12:16+00:00","mainEntityOfPage":{"@id":"https:\/\/metrolab.gr\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\/"},"wordCount":211,"publisher":{"@id":"https:\/\/metrolab.gr\/#organization"},"image":{"@id":"https:\/\/metrolab.gr\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\/#primaryimage"},"thumbnailUrl":"https:\/\/metrolab.gr\/wp-content\/uploads\/2026\/04\/Bellingham-Stanley_ADP600_2021.jpg","articleSection":["\u03a0\u03bf\u03bb\u03c9\u03c3\u03af\u03bc\u03b5\u03c4\u03c1\u03b1"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/metrolab.gr\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\/","url":"https:\/\/metrolab.gr\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\/","name":"ADP600 Series Multi-Wavelength and Temperature Controlled Polarimeters - MetroLab","isPartOf":{"@id":"https:\/\/metrolab.gr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/metrolab.gr\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\/#primaryimage"},"image":{"@id":"https:\/\/metrolab.gr\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\/#primaryimage"},"thumbnailUrl":"https:\/\/metrolab.gr\/wp-content\/uploads\/2026\/04\/Bellingham-Stanley_ADP600_2021.jpg","datePublished":"2026-04-03T11:12:16+00:00","breadcrumb":{"@id":"https:\/\/metrolab.gr\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/metrolab.gr\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/metrolab.gr\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\/#primaryimage","url":"https:\/\/metrolab.gr\/wp-content\/uploads\/2026\/04\/Bellingham-Stanley_ADP600_2021.jpg","contentUrl":"https:\/\/metrolab.gr\/wp-content\/uploads\/2026\/04\/Bellingham-Stanley_ADP600_2021.jpg","width":300,"height":300},{"@type":"BreadcrumbList","@id":"https:\/\/metrolab.gr\/adp600-series-multi-wavelength-and-temperature-controlled-polarimeters\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/metrolab.gr\/en\/"},{"@type":"ListItem","position":2,"name":"ADP600 Series Multi-Wavelength and Temperature Controlled Polarimeters"}]},{"@type":"WebSite","@id":"https:\/\/metrolab.gr\/#website","url":"https:\/\/metrolab.gr\/","name":"MetroLab","description":"\u0388\u03bd\u03b1\u03c2 \u03c3\u03c5\u03bd\u03b5\u03c1\u03b3\u03ac\u03c4\u03b7\u03c2, \u03c7\u03b9\u03bb\u03b9\u03ac\u03b4\u03b5\u03c2 \u03b5\u03c0\u03b9\u03bb\u03bf\u03b3\u03ad\u03c2 \u03b3\u03b9\u03b1 \u03c4\u03bf \u03b5\u03c1\u03b3\u03b1\u03c3\u03c4\u03ae\u03c1\u03b9\u03cc \u03c3\u03b1\u03c2","publisher":{"@id":"https:\/\/metrolab.gr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/metrolab.gr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/metrolab.gr\/#organization","name":"MetroLab","url":"https:\/\/metrolab.gr\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/metrolab.gr\/#\/schema\/logo\/image\/","url":"https:\/\/metrolab.gr\/wp-content\/uploads\/2026\/03\/logo_metrolab-1@2x-1.png","contentUrl":"https:\/\/metrolab.gr\/wp-content\/uploads\/2026\/03\/logo_metrolab-1@2x-1.png","width":409,"height":108,"caption":"MetroLab"},"image":{"@id":"https:\/\/metrolab.gr\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/metrolab.gr\/#\/schema\/person\/b98de2eb332dfc3d427dc3608e835c04","name":"praktiki","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/secure.gravatar.com\/avatar\/a717692306270715324e48aa870b6be5b99691d4444d8bb03ece104d00acd956?s=96&d=monsterid&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/a717692306270715324e48aa870b6be5b99691d4444d8bb03ece104d00acd956?s=96&d=monsterid&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/a717692306270715324e48aa870b6be5b99691d4444d8bb03ece104d00acd956?s=96&d=monsterid&r=g","caption":"praktiki"},"url":"https:\/\/metrolab.gr\/en\/author\/praktiki\/"}]}},"_links":{"self":[{"href":"https:\/\/metrolab.gr\/en\/wp-json\/wp\/v2\/posts\/1769","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/metrolab.gr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/metrolab.gr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/metrolab.gr\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/metrolab.gr\/en\/wp-json\/wp\/v2\/comments?post=1769"}],"version-history":[{"count":1,"href":"https:\/\/metrolab.gr\/en\/wp-json\/wp\/v2\/posts\/1769\/revisions"}],"predecessor-version":[{"id":1770,"href":"https:\/\/metrolab.gr\/en\/wp-json\/wp\/v2\/posts\/1769\/revisions\/1770"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/metrolab.gr\/en\/wp-json\/wp\/v2\/media\/1764"}],"wp:attachment":[{"href":"https:\/\/metrolab.gr\/en\/wp-json\/wp\/v2\/media?parent=1769"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/metrolab.gr\/en\/wp-json\/wp\/v2\/categories?post=1769"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/metrolab.gr\/en\/wp-json\/wp\/v2\/tags?post=1769"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}